ACP Portable Electrical Current Transformer Test,CT/PT Analyzer
ACP current transformer test kit is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
ACP portable current transformer test kit designed for analyzing current transformers and voltage transformers of protection or measurement use, which is suitable for laboratory and on-site test.
Application: ACP portable Current transformer analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
Tests for current transformer:
1.Excitation curve and parameters test 2.Turns ratio test 3.Ratio and phase error test 4.Polarity mark check 5.Coil resistance measurement 6.Secondary loop burden measurement 7.Error line curve test for protection CT 8.Transient CT parameters test 9.CT nameplate guess 10.Saturation hysteresis loop curve measurement
ACP Current Transformer Test Kit's Technical Parameters
No.
Item Name
ACP Current Transformer and Voltage Transformer CT PT Analyzer
1
Test standards
IEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
2
Power supply
AC220V±10%,50Hz/60Hz±10%
3
Power output
0.1~125V (AC)
4
Current output
0.001~5A(RMS)
5
Power output
300VA
6
Max. knee voltage measurement
45kv
7
Current measurement range
0~10A (automatically change range in 0.1/0.4/2/10A)
8
Current measurement error
<±0.1%+0.01%FS
9
Voltage measurement range
0~200 V (automatically change range in 1V/10V/70V/200V)
10
Voltage measurement error
< ±0.1%+0.01%FS
11
Turns ratio measurement range
1~30000;
1~2000 error<0.05%;
2000~5000 error>0.1%;
5000~35000 error<0.2%
12
Phase measurement
error: ±2min,resolution:0.01min
13
Coil resistance measurement
Range: 0~8kΩ(automatically change range in 2ohm /20ohm /80ohm/800ohm/8kohm)
Error< 0.2%RDG+0.02%FS
Maximum resolution: 0.1mΩ
14
Temperature measurement
-50~100 Celsius degree, error<3 Celsius degree
15
CT Secondary burden
Range 0-160ohm (automatically change range in 2ohm/ 20ohm/80ohm/160ohm)
Error<0.2%RDG+0.02%FS Maximum resolution 0.001ohm
16
PT Secondary burden
Range 0-80kohm (automatically change range in 800ohm / 8kohm /80kohm)